Archive for the DIAGNOSTICS/GAS FURNACES Category

Troubleshooting: How Stuff Works…and Breaks

Posted in DIAGNOSTICS/GAS FURNACES, DIAGNOSTICS/HEAT PUMPS, hvac training, troubleshooting on March 4, 2009 by wayneshirley

So, maybe you’re thinking troubleshooting heat pumps is about Ohm’s Law, psychrometric charts, Mollier diagrams, sensible heat ratios, COP’s and…etc., etc…? There are a lot of scientific principles explaining how heat pumps do what they do. And at some point in our training we eventually have to deal with some of the science in understanding heat pump operation…electricity, magnetism, thermodynamics, fluid flow dynamics…stuff like that. But fluency in scientific principles generally won’t get you to a diagnosis. I can remember a time early in my career when I could recite a lot of science to heat pump owners, but couldn’t tell them why it wasn’t working like it’s supposed to…and then there’s the engineer who posted the following comment at this website:

“..Brilliant blog! I’m just starting to wade through this stuff. Ended up here after looking for answers on diagnosing reversing valves…I’m the engineer learning how to be the tech (geothermal) for the last 3 years and I find practical/applied stuff like this invaluable. Your strength is being able to recall the time when you didn’t understand the problem and relating to that person now trying to figure it out…”

So, just what does one need to know, in order to troubleshoot? Let’s look at a hypothetical situation…

If you walk into the bathroom and flip the light switch, most of the time the light comes on. That’s a simple result of an enormous amount of science and engineering. In order for that light to come on, Ben Franklin had to discover electricity, Edison had to invent the lightbulb, Tesla and Westinghouse had to develp AC power generation…but all you and I have to know is simple circuitry: when the light switch closes, a circuit is completed allowing voltage to be supplied, causing current flow which makes the light burn. And as long as the light comes on each time the switch is flipped, we don’t generally give it a second thought.

But when the light doesn’t come on, what are the options? Well, you could go to the breaker panel and check for a tripped breaker or even take a  meter and confirm the breaker is actually transferring voltage to the circuit. If that didn’t reveal the problem, you could move to the switch and see if there is a problem there…voltage in, voltage out. If you still don’t find the problem, checking the fixture for voltage would be the next thing to do. If after all that, you haven’t found the problem, then your last test would be continuity through the bulb…

But what do we usually do when the light doesn’t come on, after the  switch is flipped? Just change the bulb, right? And why do we change the bulb  before doing all that other stuff? Because most of us know the bulb is the weak link in the chain, the most likely candidate for failure. And how do we know that? Simply from years of replacing bathroom lightbulbs…

So the conclusion of the story is…? Troubleshooting residential heating and cooling equipment is, most of the time, all about knowing how stuff works and how stuff breaks. In the  bathroom light scenario, we use our knowledge of how stuff breaks to get us to a quick and probable diagnosis. But on the few occasions where the bulb isn’t the problem, we can use our knowledge of how stuff works and “test” our way to a solution.

Let’s look at another example closer to reality for us:

Suppose you go on a 10 SEER / R-22 system service call in July, and after making some pressure and temperature measurements, come up with the following numbers:

Suction pressure… 58 psi

Head pressure…….200 psi

Superheat……………2 F

Subcooling………….15 F

An experienced technician can look at the numbers and immediately see a problem with the suction pressure / superheat values,  know what the problem is and the most likely cause…low airflow across the indoor coil, due most likely to a dirty coil. His conclusions are part science and part experience. Normal suction pressures are closer to 70 psi by design with normal superheats closer to 10 F. Most 10 SEER equipment is fixed orifice, meaning superheats  vary with operating conditions. Low suction pressure, with low superheat, is the classic symptom of low evaporator air. There’s not enough heat available to boil off the refrigerant inside the coil, resulting in less refrigerant vapor produced and excessive liquid remaining in the coil. Dirty coils being the cause is mostly a product  of experience.

Knowing how things work tells us what heat pumps are supposed to do and what it takes for them do it. With that knowledge, you can always figure out what’s wrong with a failed system. Knowing how things break quite often tells you where to start the troubleshooting process…

To Order: Click Here

For Technicians Only…

Posted in DIAGNOSTICS/GAS FURNACES, DIAGNOSTICS/HEAT PUMPS, hvac training, troubleshooting with tags , on November 5, 2008 by wayneshirley

..and I should add, techs who are a little weak in diagnostics. We always credit experience for expertise in some skill, regardless of the skill. Experience has always been the best teacher whether you’re working with heat pumps or airplanes…but experience is a somewhat generalized term leaving the inexperienced individual with little assistance in improving his skills level. In preparing presentation material recently for some “Troubleshooting Heat Pumps” seminars, I  came up with a better way (I believe) to illustrate just what experience teaches us, relative to troubleshooting.

It helps to understand the mentality needed for troubleshooting equipment as opposed to building equipment. Heat pump technology is a product of several sciences. But a heat pump unit is the application of those same sciences. And if the unit was designed and manufactured around the scientific principles, it will do what it’s supposed to do…the science is built-in at the factory. So, as technicians, we aren’t required to verify or confirm the science, just the designed operation. So…whether or not we really understand all the implications of the Second Law of Thermodynamics isn’t really an issue. The Second Law of Thermodynamics may explain in scientific terms how or why a heat pump can cool / heat the house, but it won’t tell you the filters are dirty…So just what is it we need to know in order to troubleshoot equipment? For lack of a better expression, I’m going to say, knowing how stuff works, or knowing what stuff is supposed to do. And then you can extend that definition a little and add, …and what it takes to make it do it.

As an illustration, the electricity / magnetism principles that explain why/how a motor “runs”, won’t really help you diagnose a motor that isn’t running…if it isn’t running, some of the science is obviously missing. And if it isn’t running, then it’s not doing what it’s supposed to do. If you know or can figure out what it takes to make it run, you can diagnose the failure….and what does it take to make it run, or do what it’s supposed to do? Voltage source? that’s a good place to start. Closed switch? yep. Unbroken wires/circuit connecting the voltage to the switch to the motor? absolutely. Decent bearings? a must. Good capacitor? of course.

So if you find a motor not doing what it’s supposed to do, now you know what items to test, check, etc., to determine why the motor isn’t doing what it’s supposed to do. Isn’t that far simpler than than trying to measure or analyze the magnetic fields? I would think so…

I believe you will eventually discover diagnostics is more about understanding what the engineers intended the equipment to do, than understanding the scientific principles behind just how it does it. So, when the situation has you stumped, think in terms of what the device, part or system is supposed to do and what might keep it from doing it. Some skill with that approach will help you get you through the service calls…

To Order:Click Here

DIRECT IGNITION GAS FURNACES…TEST YOUR KNOWLEDGE

Posted in DIAGNOSTICS/GAS FURNACES with tags , , on February 27, 2008 by wayneshirley

On a call for heat, the furnace makes it all the way to ignition and firing takes place for a few seconds, then the gas valve de-energizes…the LED blinks an “ignition failure” code…your first choice for the suspect cause would be:

a) faulty gas valve

b) faulty flame sense circuit

c) faulty control board

d) faulty roll-out switch

To Order: Click Here

TROUBLESHOOTING FURNACES…IDENTIFYING THE WIRING ON 80% HSI FURNACES

Posted in DIAGNOSTICS/GAS FURNACES with tags , , on February 8, 2008 by wayneshirley

Knowing how stuff works goes a long way in being able to understand what’s wrong when they don’t… the following clip is from the “Troubleshooting 80% HSI Gas Furnaces” DVD…

TROUBLESHOOTING GAS FURNACES…CHECK THAT SUPPLY PRESSURE

Posted in DIAGNOSTICS/GAS FURNACES with tags , , , , , on February 3, 2008 by wayneshirley

Furnace failures will occasionally be the result of a gas supply problem, rather than an actual failure with the furnace components. Overlooking this possibility can result in a potentially embarrassing and expensive situation, to say the least…

TROUBLESHOOTING FURNACES…HSI FURNACE FIRING SEQUENCE

Posted in DIAGNOSTICS/GAS FURNACES with tags , , , on February 3, 2008 by wayneshirley

Knowing how auto-ignition furnaces are supposed to operate on a call for heat, and understanding what takes place during the ignition sequence can go a long way in helping diagnose problems. This is especially true if the furnace doesn’t have the “little red light” to give you a failure code…